    In HVT (High Voltage Technology), any voltage above 11 kilo-volts is known as inside the high voltage range. It may either be alternating or household power. Tastes industries are given using this type of selection of voltages from your national grid even though some generates their own hollywood power using power generators. These high voltages usually are stepped right down to some specific lower voltages, to own their electrical machinery including motors, heaters, HVAC systems, among others. For these industries, regular checks should be conducted by authorized personnel to assess the healthiness of their equipment. Equipment tests are very essential in determining the soundness of an machine to be able to avoid equipment breakdown and large production losses. These tests also help in determining if your newly purchased devices are worth, before installing it. Most manufacturers use high voltage testing to evaluate the insulation of the equipment before giving them with their customers.

    The advantages of applying high voltage insulation testing are often looked down upon by many industries, like a means of determining the conditionality of the electrical equipment. This is greatly due to the reality that much pressure and emphasis is usually place on production activities in the tariff of proactive repair of the gear. The best and effective insulation with an electrical machine is very important because of its correct operation each time. Since insulation of kit degrades eventually, the respective electrical department for almost any industry have to be regularly conducting regular check-ups for machines as part of their normal working schedule. Do that to even low and medium voltage systems.

    In most cases, a four stage process is followed. The stages are briefly described below:

    In-process testing

    Here is the most basic process which can be done even for the readily installed equipment, as long as it’s not at all running. This technique necessitates the use of a meggering instrument to try the insulation integrity of the coils prior to it being linked to phases, neutral, and earth. Occasionally, a multimeter could also be used. Inter-winding and winding-to-body resistances are checked at this time. Therefore, the dielectric withstanding voltage and insulation resistance in the coil can be discovered.

    Ancillary Equipment Testing

    This calls for testing for insulation resistance and dielectric withstanding voltage for interconnecting cables, high profile bushings, busbars, and terminations. This is conducted if the components are interconnected or separated.

    Generator Assembly Test

    In cases like this the generator is visually inspected. Cleaning is completed as well as the machine’s stability is also assessed. The heartbeat of the machine is closely monitored by using a special display instrument. The equipment is also meggered for insulation resistance and dielectric withstanding voltage test.

    One of the considerations in testing equipment are; voltage and right testing equipment. For the best dependable results testing voltage should be high enough to effectively appraise the insulating resistance. However, it should not be too much to overstress the device insulation. The proper testing equipment which can effectively store results permits them to be held in a pc for archiving and analysis. This treatment saves serious amounts of reduces the chance of error.